Chapter 4 provides additional guidance for the design of structures other than buildings.
Ufc 3 301 01 update#
The climatic and seismic data included in this UFC are intended as a tool to assist in the consistent interpretation of the corresponding data in the IBC at significant DoD installations within the United States, and as the basis for applying the provisions of UFC 1-200-01 to significant DoD installations outside of the United States. This paper documents our update of the tabulated ground motion values in the 2013 edition of UFC 3-301-01, for consistency with ASCE 7-10 and ASCE 41-13. Chapter 3 of this UFC further modifies ASCE/SEI 7-10 for structural-specific design requirements and is organized by the chapter of ASCE/SEI 7 that each section modifies. Chapter 2 of this UFC further modifies the IBC for structural-specific design requirements and is organized by the chapter of IBC that each section modifies.

Ufc 3 301 01 code#
UFC 1-200-01 uses and supplements IBC 2012 as the building code for DoD. This information shall be used by structural engineers to develop design calculations, specifications, plans, and design-build Requests for Proposal (RFPs). These technical requirements are based on the 2012 International Building Code (IBC 2012), as modified by UFC 1-200- 01.

For more titles published by 4th Watch Books, please visit: 3-301-01, UNIFIED FACILITIES CRITERIA (UFC): STRUCTURAL ENGINEERING (0)., This Unified Facility Criteria (UFC) provides requirements for structures designed and constructed for the Department of Defense (DoD). 4th Watch Books is a Service Disabled Veteran-Owned Small Business (SDVOSB). UFC 3-301-01 1 June 2013 Change 1, FOREWORD The Unified Facilities Criteria (UFC) system is prescribed by MIL-STD 3007 and provides planning, design, construction, sustainment, restoration, and modernization criteria, and applies to the Military Departments, the Defense Agencies, and the DoD Field Activities in accordance with USD. We publish compact, tightly-bound, full-size books (8 1/2 by 11 inches), with glossy covers. It's much more cost-effective to just order the latest version from This book is published by 4th Watch Books and includes copyright material. If you are paid more than $10 an hour and use an ink jet printer, buying this book will save you money.

An engineer that's paid $75 an hour has to do this himself (who has assistant's anymore?). If it's just 10 pages, no problem, but if it's a 250-page book, you will need to punch 3 holes in all those pages and put it in a 3-ring binder. Then you gotta print it using a network printer you share with 100 other people - and its outta paper - and the toner is low (take out the toner cartridge, shake it, then put it back). 2-1.6 Section 1613 - EARTHQUAKE LOADS 2-1.6.1 1613.3.1.1 - Specific Locations Within the United States Addition Seismic parameters at DoD installations within the United States and its territories and possessions are identified in Table E-3 of UFC 3-301-01 to facilitate consistent interpretation of the information provided in Figures 1613.3.1(1) through 1613.3.1(6). Hill Fort Belvoir Fort Eustis Fort Lee Fort Monroe Fort Myer Fort Story Henderson Hall / Arlington Langley AFB / Hampton NAB Little Creek Norfolk Region.
Ufc 3 301 01 download#
Why buy a book you can download for free? First you gotta find it and make sure it's the latest version (not always easy). UFC 3-301-01 1 June 2013 Change 1, 13 Vult ultimate design wind speed determined from Figure 1609A. UFC 3-301-01 27 January 2010 With Change 2, 31 January 2011 TABLE E-2 State Utah Virginia Base / City Salt Lake City Tooele Army Depot Dahlgren Dam Neck / Virginia Beach Ocean front Fort A.

This Unified Facility Criteria (UFC) provides requirements for structures designed and constructed for the Department of Defense (DoD). Includes a list of applicable NIST cybersecurity publications for consideration. UFC 3-301-01, 13th Edition, STRUCTURAL ENGINEERING.
Ufc 3 301 01 manual#
It is not the intent of this manual to duplicate information contained in the standards cited herein, but to reference them as appropriate. This UFC provides minimum standards to safeguard life or limb, health, property and public welfare by regulating and controlling the design, construction, installation, quality of materials, location, operation, and use of plumbing systems.